Primer-enamel epoxy-vinyl
  • Color: various (tinting according to the RAL catalogue). Finish: matte
  • Packing: Double-packed

Description

Double-packed epoxy-vinyl primer-enamel.
It has excellent adhesion to steel, zinc-plated and aluminum surfaces.

Recommended use 

Protective and decorative painting of  steel, zinc-plated and aluminum structures  operating in atmospheric conditions of all macroclimate areas, atmosphere types and placement categories according to GOST 15150.  Oil-, gasoline-proof coating is  resistant to  exposure  to  aggressive  environments,  oil and petroleum products spills, sea and fresh water,  sudden temperature changes (from minus 60 to plus 60 °C), short-term exposure to hot water and steam.
Used as:

  • independent coating;
  • finishing  coat  in complex coating systems with primers VINICOR-marine  (TU 20.30.12-004-67503963-2018), VINICOR-ecoprime  (TU 2312-002-67503963-2011), ZINEP  (TU 20.30.12-022-12288779-2018), ZINOTAN (TU 2312-017-12288779-2003), ZINOL (TU 2313-012-12288779-99), as well as with other epoxy-based primers.
It is allowed to apply primer-enamel on  consolidated residual  corrosion products and old coatings based on alkyd, vinyl, epoxy-vinyl and epoxy materials.

Certificates, Approvals

State registration certificate No. KG.11.01.09.008.Е.002735.03.23

Approved by test centers: Scientific Industrial Holding “Lakokrasprotiye”; FSUE “Promethey” as part of a coating system with VINICOR-marine primer (TU 2312 004-67503963-2012).

It has a certificate of voluntary certification system of the Russian River Register No. РОСС RU.PO00.H00269.

Technical data

Diluent
Р-4, ksilol
Mass fraction of non-volatile substances
39–45 %
Viability
24 hours, t (20±2)°С
Dry film thickness
50–100 mkm

Surface preparation

Steel surface:

  • degrease metal surface to 1 grade according to GOST 9.402;
  • minimum:  power or hand tool  cleaning of rust to  3 or 4  grade  according to GOST 9.402 (St 2 according to ISO 8501-1);
  • recommended: abrasive blast  cleaning  from scale, rust and traces of old paint  to  2  grade according to GOST 9.402 (Sa 2½ according to ISO 8501-1);
  • remove dust.

Zinc-plated surface:
  • degrease metal surface to 1 grade according to GOST 9.402;
  • the surface should have a roughness (if necessary,  use  polishing  paper or a non-metallic abrasive);
  • remove dust.
Aluminum surface:
  • degrease the metal surface to 1 grade according to GOST 9.402;
  • power or hand  tool  cleaning using  polishing paper  or non-metallic abrasive to create a rough surface;
  • remove dust.
Before applying the second layer, the coating must be dry, clean, oil and dust shall be removed.

Application 

  • mix base thoroughly to homogenous condition before application;
  • with constant stirring, add a hardener to the base and mix thoroughly.
The mixing ratio of the base and EN-06 hardener 100:0.84 by mass.
  • if necessary, the composition should be diluted to the working viscosity;
  • holding time of the prepared material before application is 15-20 minutes, covered with a lid.
The material is recommended to be applied in the plant and field conditions at a temperature from  minus  10  to  plus  35  °C  and  relative  air  humidity  not more than 85  %.  The temperature of the painted  surface shall be above the dew point by at least 3 °C. 
The primer-enamel  is recommended to be applied in 1-2 layers using airless,  conventional  (air)  spray by brush/roller.

Storage and handling

The material  is delivered in packages: base and hardener packed in metal buckets and metal cans respectively depending on the set weight.
Storage conditions of  primer-enamel components  –  according to GOST 9980.5 (at temperature from minus 40 to plus 40 °C). The container shall be protected from atmospheric condensation and direct sunlight.
The  shelf life  is determined by warranty storage of the base (24 months) and hardener (12 months) starting with the manufacture date.

Precautions

When working with the  material,  one shall observe the existing sectoral standard norms and requirements and safety measures as specified on the package label.
One shall use personal protective equipment (goggles, face masks and respirators) and avoid inhalation of thinners and contact of the composition or its components with skin, eye mucosa, respiratory channels; use inside the premises is allowed only in case sufficient ventilation is provided.
The material and its components (base and hardener) are fire-hazardous!
The hardened coating is not harmful to human health.

The information is of general character, without consideration to the object specific nature. Use of materials for other  purposes not specified here or in case other influencing factors are present shall be approved by  the VMP Holding CJSC in  writing. In case of absence of such approval the manufacturer is not held liable for the improper use of the material and the buyer falls from the right to present claims connected with the coating quality.



For qualified assistance in selecting the optimal protective coating system, please contact LLP "VMP ASTANA PLANT": +7 (7172) 69-53-74.
Also, for the convenience of users, the site operates an  On-line request.